All Products 21.0 HF2 - Fixed bugs

Reference Summary Fixed also with
ACI0097827 On Windows, for engined application or engined client /server, custom icon isn't display in several windows 21 R2 20.8 HF3
ACI0105285 Debugger window blinks and closes if a saved expression does an HTTP request and wait. 21 R2
ACI0106081 When a web area in a form loads HTML page with a dropdown, selecting any dropdown option pauses 'On Timer' form event. 20.8 HF3
ACI0106179 4D Write Pro: When merging two or more cells vertically, the background image in the merged area is zoomed. 21 R2
ACI0106180 In the dialog box for exporting data to a file, if you change forms, 4D may quit unexpectedly. 21 R2
ACI0106186 The "DELETE SELECTION" command takes 0.5s to execute even if the table is empty. 21 R2
ACI0106189 Connection problems to 4D Server with the network component QUIC if using a VPN. 21 R2
ACI0106203 'License usage' command: 'session.IPAddress' is empty since 4D v21 21 R2
ACI0106204 When dictating text in a text area using the voice-to-speech feature of macOS, the dictated text is deleted after four lines of text.
ACI0106207 The 4D command 'VERIFY CURRENT DATA FILE' doesn't set the variable 'OK' to 0 if the callback method doesn't exist. 21 R2
ACI0106211 In the dialog box for exporting data to a file, on the Form tab, when you switch tables, the form preview is not updated.
ACI0106212 In the dialog box for exporting data to a file, if you select a table without a form, you can no longer select another table.
ACI0106213 In some cases, with an engine client, after using the “CHANGE USER” command, the 4D user selection window appears at launch, which should not be the case because there is a default user. 21 R2
ACI0106223 The Windows compatibility option "Use DirectWrite" is hidden under macOS. The option should be visible on macOS too (as on Windows). 21 R2
ACI0106229 For engined application or engined client /server, custom icon isn't display in several windows when build with Build4d component
ACI0106232 CEF (Chromium Embedded Framework), used in all web area, doesn't work when 4D is started in "Run as administrator" mode. 21 R2
ACI0106233 4D fails to manage or to open windows correctly once a certain number of windows is reached (typically 80+ project method windows) 21 R2
ACI0106238 In the window title of an entry form in 'User Mode', a space char is missing between "Entry For" and "TableName".
ACI0106246 Double Clicking Explorer's Scrollbar Opens Highlighted Item 21 R2
ACI0106251 4D Write Pro: if a style (e.g. italic, bold) is not supported for a font, the check box with the associated standard action is not disabled.
ACI0106252 For an engineered server, the title of the server administration window contains 4D Server. 21 R2
ACI0106254 Object Set Format incorrectly resets the size icons to 0x0 21 R2